| Name: |
Human MCP-1(Monocyte Chemotactic Protein 1) ELISA Kit |
|||
| Adapted species: | Human | |||
| Specifications: | 48T/96T | |||
| Storage: | Store at 2-8 ℃ for 6 months | |||
| Application: | Human MCP-1(Monocyte Chemotactic Protein 1) ELISA Kit can quantitatively determine the concentration of IL-12 in plasma, tissue homogenates, and other biological fluids in vitro | |||
| Testing method: | Double Antibody Sandwich Method | |||
| Detection range: | 15.625-1000pg/ml | |||
| Sensitivity: | < 9.375pg/ml | |||
| Standard curve: | ![]() |
|||
| Rate of recovery: | Add a certain amount of MCP-1 to the samples listed in the table below, and calculate the recovery rate by comparing the measured values with the expected amount of MCP-1 in the samples | |||
| sample | Recycling range (%) | Average value (%) | ||
| Serum (n=5) | 85-101 | 92 | ||
| EDTA plasma (n=5) | 90-103 | 95 | ||
| Heparin plasma (n=5) | 89-105 | 98 | ||
| Linearity: | The linearity of the reagent kit is determined by detecting samples and their series of dilutions mixed with appropriate concentrations of MCP-1, expressed as a percentage of the detected concentration relative to the expected concentration | |||
| sample | 1:2 | 1:4 | 1:8 | |
| Serum (n=5) | 89-104% | 88-103% | 86-100% | |
| EDTA plasma (n=5) | 84-98% | 83-98% | 82-101% | |
| Heparin plasma (n=5) | 88-98% | 82-98% | 80-93% | |
| Coefficient of variation (%): | Intra batch difference: CV<8% Inter batch difference: CV<10% | |||
| Matters needing attention: | For scientific research purposes only | |||