Rat Interleukin 6 (IL-6) ELISA Kit instruction
|
|
|
Specifications |
48T/96T |
|
article number |
ADL01597R1
|
|
Species |
rat |
|
Sample type |
serum, plasma, tissue homogenate,cell lysate, cell Culture supernatant etc. |
|
Detection range |
See the manual for details |
|
Sensitivity |
See the manual for details |
|
Response time |
1-5h |
|
Sample volume |
100μL |
|
Detection wavelength |
450nm |
|
Delivery date |
3-5 days |
|
Manual |
Consult our salesperson for obtaining |
Recovery rate
The target protein of known concentration was added to 5 different samples, and the recovery experiment was performed to obtain the recovery range and average recovery rate.
|
Sample Type |
Range (%) |
Average Recovery (%) |
|
Serum (n=5) |
94-110 |
102 |
|
EDTA plasma (n=5) |
90-102 |
96 |
|
Cell culture media (n=5) |
95-106 |
98 |
Linear
Add the target protein of known concentration to 5 samples respectively, do recovery experiment, get the range of recovery rate and average recovery rate. Dilute 5 samples by 2 times, 4 times, 8 times, and 16 times respectively for recovery experiments to obtain the recovery range and average recovery rate.
|
Sample |
1:2 |
1:4 |
1:8 |
1:16 |
|
Serum (n=5) |
99-108% |
95-109% |
89-103% |
88-102% |
|
EDTA plasma (n=5) |
95-105% |
90-100% |
89-104% |
98-108% |
|
Cell culture media (n=5) |
92-104% |
97-105% |
96-108% |
92-105% |
Specificity
This kit recognizes natural and Rat soluble E-selectin, and has no obvious cros-reactivity with other similar substances. Due to the limitation of technology and sample source, it is impossible to complete the cross-reaction test of all related or similar substances. Therefore, this kit may have cross-reaction with other untested substances.
Stability
It has been determined that the kit must be stored at the recommended temperature within the validity period, and the activity reduction rate is less than 5%. In order to reduce the influence of external factors on the detection value before and after the destruction of the kit, the environmental conditions of the laboratory should be kept as consistent as possible, especially the temperature, humidity and incubation conditions in the laboratory. Secondly, the operation by the same experimenter can reduce human error.
Kit composition
|
Serial number |
English name |
specification |
|
1 |
Wash solution(30X) |
20ml×1 bottle |
|
2 |
HRP-Conjugate reagent |
6ml×1 bottle |
|
3 |
Microelisa stripplate |
12 holes×8 strips |
|
4 |
Sample diluent |
6ml×1 bottle |
|
5 |
Chromogen Solution A |
6ml×1 bottle |
|
6 |
Chromogen Solution B |
6ml×1/bottle |
|
7 |
Stop solution |
6ml×1 bottle |
|
8 |
Standard |
0.5ml×1 bottle |
|
9 |
Standard diluent |
1.5ml×1 bottle |
|
10 |
Product Description |
1 serving |
|
11 |
Sealing plate membrane |
2 sheets |
|
12 |
Sealing bag |
1 piece |
Note: Please check whether the label and quantity of the reagents in the kit are consistent with the table before use.
Storage conditions and validity period
1. Store at 2-8℃, do not freeze, the validity period is 6 months.
2. After opening and use, put the coated microplate into a ziplock bag with desiccant, seal the ziplock bag, and put all reagents back into the refrigerator at 2-8°C.